Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
Radiology ; 311(1): e232806, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38563670

RESUMO

Background The increasing use of teleradiology has been accompanied by concerns relating to risk management and patient safety. Purpose To compare characteristics of teleradiology and nonteleradiology radiology malpractice cases and identify contributing factors underlying these cases. Materials and Methods In this retrospective analysis, a national database of medical malpractice cases was queried to identify cases involving telemedicine that closed between January 2010 and March 2022. Teleradiology malpractice cases were identified based on manual review of cases in which telemedicine was coded as one of the contributing factors. These cases were compared with nonteleradiology cases that closed during the same time period in which radiology had been determined to be the primary responsible clinical service. Claimant, clinical, and financial characteristics of the cases were recorded, and continuous or categorical data were compared using the Wilcoxon rank-sum test or Fisher exact test, respectively. Results This study included 135 teleradiology and 3474 radiology malpractices cases. The death of a patient occurred more frequently in teleradiology cases (48 of 135 [35.6%]) than in radiology cases (685 of 3474 [19.7%]; P < .001). Cerebrovascular disease was a more common final diagnosis in the teleradiology cases (13 of 135 [9.6%]) compared with the radiology cases (124 of 3474 [3.6%]; P = .002). Problems with communication among providers was a more frequent contributing factor in the teleradiology cases (35 of 135 [25.9%]) than in the radiology cases (439 of 3474 [12.6%]; P < .001). Teleradiology cases were more likely to close with indemnity payment (79 of 135 [58.5%]) than the radiology cases (1416 of 3474 [40.8%]; P < .001) and had a higher median indemnity payment than the radiology cases ($339 230 [IQR, $120 790-$731 615] vs $214 063 [IQR, $66 620-$585 424]; P = .01). Conclusion Compared with radiology cases, teleradiology cases had higher clinical and financial severity and were more likely to involve issues with communication. © RSNA, 2024 See also the editorial by Mezrich in this issue.


Assuntos
Imperícia , Radiologia , Telemedicina , Telerradiologia , Humanos , Estudos Retrospectivos
2.
Acad Radiol ; 31(1): 1-6, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37271637

RESUMO

RATIONALE AND OBJECTIVES: The Omicron variant of COVID-19 is less severe than the ancestral strain, leading to the potential for deaths in patients infected with the virus but who die of other causes. This study evaluated the difference in rates of pneumonia among patients who died with SARS-CoV-2 infection in the ancestral vs Omicron eras. MATERIALS AND METHODS: We identified patients who died within 30days of a positive SARS-CoV-2 test, from March 2020 through December 2022; variants were assigned based on the prevalent variant in the US at that time. We also obtained a control group from patients who died within 30days of a negative SARS-CoV-2 test in January 2022. The first CT after the test was reviewed in a blinded fashion and assigned a category from the RSNA Consensus Reporting Guidelines. The primary outcome was the difference in rates of positive (typical or indeterminate) COVID-19 findings in the ancestral vs Omicron eras. RESULTS: A total of 598 patients died during the ancestral era and 400 during the Omicron era, and 347 decedents comprised the control group. The rate of positive COVID-19 findings was 67/81 (83%) in the ancestral era and 43/81 (53%) in the Omicron era (P < .001), an absolute difference of 30% (95% CI 16%-43%). The rate of positive findings in the control group was 23/76 (30%). CONCLUSION: During the Omicron era, 30% fewer SARS-CoV-2-associated deaths were associated with COVID-19 pneumonia and were caused either by nonpulmonary effects of the infection or were unrelated to the infection.


Assuntos
COVID-19 , Pneumonia , Humanos , Prevalência , SARS-CoV-2
3.
Radiol Clin North Am ; 61(6): 1085-1096, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37758358

RESUMO

Dual-energy computed tomography affords emergency radiologists with important tools to aid in the detection and discrimination of commonly encountered ED pathologies. In doing so, it can increase the speed of diagnosis and diagnostic certainty while sparing patients potentially unnecessary downsteam workups and radiation exposure. This article demonstrates these clinical benefits through a case-based approach.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos
4.
Clin Exp Gastroenterol ; 16: 55-58, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37131985

RESUMO

Patients with gastrointestinal (GI) bleeding present to the emergency department (ED) with a wide spectrum of illness severity. Among the most critically ill patients, comorbidities and other risk factors, such as liver disease and anticoagulation, can complicate their management. These patients are resource-intensive to stabilize and resuscitate, often requiring the continuous attention of multiple ED staff members along with rapid mobilization of specialty care. At a tertiary care hospital with the ability to provide definitive care for the most critically ill patients with GI bleeding, we introduced a multi-disciplinary team activation pathway to bring together specialists to immediately respond to the ED. We designed a Code GI Bleed pathway to expedite hemodynamic stabilization, diagnostics, source control, and timely disposition out of the ED to the intensive care unit or relevant procedural area of the hospital.

5.
Emerg Radiol ; 30(3): 267-277, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36913061

RESUMO

PURPOSE: There is a growing body of diagnostic performance studies for emergency radiology-related artificial intelligence/machine learning (AI/ML) tools; however, little is known about user preferences, concerns, experiences, expectations, and the degree of penetration of AI tools in emergency radiology. Our aim is to conduct a survey of the current trends, perceptions, and expectations regarding AI among American Society of Emergency Radiology (ASER) members. METHODS: An anonymous and voluntary online survey questionnaire was e-mailed to all ASER members, followed by two reminder e-mails. A descriptive analysis of the data was conducted, and results summarized. RESULTS: A total of 113 members responded (response rate 12%). The majority were attending radiologists (90%) with greater than 10 years' experience (80%) and from an academic practice (65%). Most (55%) reported use of commercial AI CAD tools in their practice. Workflow prioritization based on pathology detection, injury or disease severity grading and classification, quantitative visualization, and auto-population of structured reports were identified as high-value tasks. Respondents overwhelmingly indicated a need for explainable and verifiable tools (87%) and the need for transparency in the development process (80%). Most respondents did not feel that AI would reduce the need for emergency radiologists in the next two decades (72%) or diminish interest in fellowship programs (58%). Negative perceptions pertained to potential for automation bias (23%), over-diagnosis (16%), poor generalizability (15%), negative impact on training (11%), and impediments to workflow (10%). CONCLUSION: ASER member respondents are in general optimistic about the impact of AI in the practice of emergency radiology and its impact on the popularity of emergency radiology as a subspecialty. The majority expect to see transparent and explainable AI models with the radiologist as the decision-maker.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Estados Unidos , Motivação , Radiologia/educação , Radiologistas , Inquéritos e Questionários
6.
AJR Am J Roentgenol ; 220(5): 693-704, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36416399

RESUMO

BACKGROUND. Adrenal masses are often indeterminate on single-phase postcontrast CT. Dual-energy CT (DECT) with three-material decomposition algorithms may aid characterization. OBJECTIVE. The purpose of this study was to compare the diagnostic performance of metrics derived from portal venous phase DECT, including virtual noncontrast (VNC) attenuation, fat fraction, iodine density, and relative enhancement ratio, for characterizing adrenal masses. METHODS. This retrospective study included 128 patients (82 women, 46 men; mean age, 64.6 ± 12.7 [SD] years) who between January 2016 and December 2019 underwent portal venous phase abdominopelvic DECT that showed a total of 139 adrenal lesions with an available reference standard based on all imaging, clinical, and pathologic records (87 adenomas, 52 nonadenomas [48 metastases, two adrenal cortical carcinomas, one ganglioneuroma, one hematoma]). Two radiologists placed ROIs to determine the following characteristics of the masses: VNC attenuation, fat fraction, iodine density normalized to portal vein, and for masses with VNC greater than 10 HU, relative enhancement ratio (ratio of portal venous phase attenuation to VNC attenuation). Readers' mean measurements were used for ROC analyses, and clinically optimal thresholds were derived as thresholds yielding the highest sensitivity at 100% specificity. RESULTS. Adenomas and nonadenomas were significantly different (all p < .001) in VNC attenuation (mean ± SD, 18.5 ± 12.9 vs 34.1 ± 8.9 HU), fat fraction (mean ± SD, 24.3% ± 8.2% vs 14.2% ± 5.6%), normalized iodine density (mean ± SD, 0.34 ± 0.15 vs 0.17 ± 0.17), and relative enhancement ratio (mean ± SD, 186% ± 96% vs 58% ± 59%). AUCs for all metrics ranged from 0.81 through 0.91. The metric with highest sensitivity for adenoma at the clinically optimal threshold (i.e., 100% specificity) was fat fraction (threshold, ≥ 23.8%; sensitivity, 59% [95% CI, 48-69%]) followed by VNC attenuation (≤ 15.2 HU; sensitivity, 39% [95% CI, 29-50%]), relative enhancement ratio (≥ 214%; sensitivity, 37% [95% CI, 25-50%]), and normalized iodine density (≥ 0.90; sensitivity, 1% (95% CI, 0-60%]). VNC attenuation at the traditional true noncontrast attenuation threshold of 10 HU or lower had sensitivity of 28% (95% CI, 19-38%) and 100% specificity. Presence of fat fraction 23.8% or greater or relative enhancement ratio 214% or greater yielded sensitivity of 68% (95% CI, 57-77%) with 100% specificity. CONCLUSION. For adrenal lesions evaluated with single-phase DECT, fat fraction had higher sensitivity than VNC attenuation at both the clinically optimal threshold and the traditional threshold of 10 HU or lower. CLINICAL IMPACT. By helping to definitively diagnose adenomas, DECT-derived metrics can help avoid downstream imaging for incidental adrenal lesions.


Assuntos
Adenoma , Neoplasias do Córtex Suprarrenal , Doenças das Glândulas Suprarrenais , Neoplasias das Glândulas Suprarrenais , Adenoma Adrenocortical , Iodo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Benchmarking , Sensibilidade e Especificidade , Adenoma Adrenocortical/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/secundário
7.
J Digit Imaging ; 36(2): 700-714, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36417024

RESUMO

Current AI-driven research in radiology requires resources and expertise that are often inaccessible to small and resource-limited labs. The clinicians who are able to participate in AI research are frequently well-funded, well-staffed, and either have significant experience with AI and computing, or have access to colleagues or facilities that do. Current imaging data is clinician-oriented and is not easily amenable to machine learning initiatives, resulting in inefficient, time consuming, and costly efforts that rely upon a crew of data engineers and machine learning scientists, and all too often preclude radiologists from driving AI research and innovation. We present the system and methodology we have developed to address infrastructure and platform needs, while reducing the staffing and resource barriers to entry. We emphasize a data-first and modular approach that streamlines the AI development and deployment process while providing efficient and familiar interfaces for radiologists, such that they can be the drivers of new AI innovations.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiologistas , Radiologia/métodos , Aprendizado de Máquina , Diagnóstico por Imagem
8.
Abdom Radiol (NY) ; 48(2): 796-805, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36383241

RESUMO

BACKGROUND: Risk stratification is challenging in the growing population of geriatric patients requiring emergency surgery. Sarcopenia, which assesses muscle bulk, is a surrogate for frailty and predicts 1-year mortality, but does not incorporate potentially valuable additional information about muscle quality. OBJECTIVE: To describe five different CT methods of measuring sarcopenia and muscle quality and to determine which method has the greatest sensitivity for predicting 1-year mortality following emergency abdominal surgery in elderly patients. METHODS: This retrospective study includes 297 patients 70 years and older who underwent "urgent" or "emergent" laparotomy or laparoscopy for acute abdominal disease between 2006 and 2011 at a single quaternary academic medical center. All patients received a CT abdomen and pelvis with intravenous contrast within 1 month of surgery. Five different methods were applied to the psoas muscles on CT: method 1 (total psoas index TPI, which is total psoas area TPA normalized by height), method 2 ("pseudoarea" = anterior-posterior × transverse dimensions), method 3 (average HU), method 4 (TPA × HU), and method 5 ("pseudoarea" × HU). RESULTS: For all five CT measures, mortality was greatest for the lowest quartile by univariate and adjusted Cox proportional hazard analyses at all time points up to 1-year. The C-statistic was highest for Method 4, using a composite index of TPA and Hounsfield Units, indicating the greatest predictive ability to estimate mortality at all time points. CONCLUSION: Muscle quality and muscle size can be used in tandem to refine risk assessment of older patients undergoing emergency abdominal surgery. Routine calculation of the composite score of psoas cross-sectional area and HU in the emergency room setting may provide surgeons and patients valuable insight on the risk of 1-year mortality to guide preoperative decision-making and counseling. CLINICAL IMPACT: Muscle quality and size, both strong independent predictors of surgical outcomes in older patients undergoing emergency abdominal surgery, may be used in tandem to refine risk assessment. A composite score of psoas muscle cross-sectional area and Hounsfield units on CT may provide insight on 1-year mortality in this patient population.


Assuntos
Sarcopenia , Humanos , Idoso , Projetos Piloto , Estudos Retrospectivos , Fatores de Risco , Sarcopenia/diagnóstico por imagem , Sarcopenia/epidemiologia , Abdome/cirurgia , Tomografia
9.
Radiol Clin North Am ; 61(1): 111-118, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36336384

RESUMO

Establishing an emergency radiology division in a practice that has long-standing patterns of operational routines comes with both challenges and opportunities. In this article, considerations around scheduling and staffing, compensation, and equity and parity are provided with supporting literature references. Furthermore, a panel of experts having established, grown and managed emergency radiology divisions in North America and Europe share their experiences through a question and answer format.


Assuntos
Admissão e Escalonamento de Pessoal , Radiologia , Humanos , Europa (Continente)
10.
Semin Ultrasound CT MR ; 43(4): 280-292, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35738814

RESUMO

Dual-energy computed tomography (DECT) has developed into a robust set of techniques with increasingly validated clinical applications in neuroradiology. We review some of the most common applications in neuroimaging along with demonstrative case examples that showcase the use of this technology in intracranial hemorrhage, stroke imaging, trauma imaging, artifact reduction, and tumor characterization.


Assuntos
Neuroimagem , Tomografia Computadorizada por Raios X , Humanos , Hemorragias Intracranianas , Neuroimagem/métodos , Tomografia Computadorizada por Raios X/métodos
11.
Emerg Radiol ; 29(3): 461-469, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35237937

RESUMO

PURPOSE: To test the hypothesis that an automated post-processing workflow reduces trauma panscan exam completion times and variability. METHODS: One-hundred-fifty consecutive trauma panscans performed between June 2018 and December 2019 were included, half before and half after implementation of an automated software-driven post-processing workflow. Acquisition and reconstruction timestamps were used to calculate total examination time (first acquisition to last reformation), setup time (between the non-contrast and contrast-enhanced acquisitions), and reconstruction time (for the contrast-enhanced reconstructions and reformations). The performing technologist was recorded and accounted for in analyses using linear mixed models to assess differences between the pre- and post-intervention groups. RESULTS: Exam, setup, and recon times were (mean ± standard deviation) 33.5 ± 4.6, 9.2 ± 2.4, and 23.6 ± 4.7 min before and 27.8 ± 1.5, 8.9 ± 1.4, and 18.9 ± 1.7 min after intervention. These reductions of 5.7 and 4.7 min in the mean exam and recon times were statistically significant (p < 0.001) while the setup time was not (p = 0.49). The reductions in standard deviation were statistically significant for exam and recon times (p < 0.0001) but not for setup time (p = 0.13). All automated panscans were completed within 36 min, versus 65% with the traditional workflow. CONCLUSION: Automation of image reconstruction workflow significantly decreased mean exam and reconstruction times as well as variability between exams, thus facilitating a consistently rapid imaging assessment, and potentially reducing delays in critical management decisions.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Fluxo de Trabalho
12.
Curr Probl Diagn Radiol ; 51(3): 334-339, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34364734

RESUMO

BACKGROUND: Detection of fat content in thymic lesions is crucial to differentiate thymic hyperplasia from thymic tumors or other anterior mediastinal pathologies. PURPOSE: To assess the feasibility of dual-energy CT (DECT) fat content quantification for the differentiation of anterior mediastinal lesions from benign thymic lesions and the normal spectrum of the thymus. MATERIALS AND METHODS: Chest DECT images of 465 patients (median 61 years, 63% female) were visually evaluated by two radiologists and semiquantitatively scored based on the degree of fatty degeneration ranging from completely fatty (score 0) to predominantly soft-tissue (score 3), and anterior mediastinal mass (score 4). A subset of scans (n =134 including all cases with scores 2-4 and 20 randomly-selected cases from scores 0 and 1) underwent quantitative DECT analysis (fat fraction, iodine density, and conventional CT value). DECT values were compared across the semiquantitative scores. RESULTS: Results of visual evaluation included 35 with predominantly solid thymus (score 3) and 15 with anterior mediastinal mass (score 4). The most common clinical diagnoses of the 15 masses (including 8 with pathologic confirmation) were metastases (n = 10) and lymphoma (n = 4). CT values in the abnormal thymus were significantly higher than those in score 3 (median: 69.7 HU versus 19.9 HU, P <0.001). There was no significant difference in iodine density values (median: 1.7 mg/ml versus 1 mg/ml, P = 0.09). However, the fat fraction value was significantly lower in the abnormal thymus (score 4) than in the predominantly soft-tissue attenuation thymuses (score 3) (median: 12.8% versus 38.7%, P <0.001). ROC curve analysis showed that fat fraction had an AUC of 0.96 (P <0.001), with a cutoff of <39.2% fat fraction yielding 100% sensitivity and 85% specificity. CONCLUSION: DECT fat fraction measurements of the thymus may provide additional value in distinguishing anterior mediastinal lesions from benign thymus. Use of DECT may reduce the need for subsequent imaging evaluation.


Assuntos
Iodo , Linfoma , Hiperplasia do Timo , Neoplasias do Timo , Feminino , Humanos , Iodo/análise , Linfoma/diagnóstico por imagem , Linfoma/patologia , Masculino , Hiperplasia do Timo/diagnóstico por imagem , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Tomografia Computadorizada por Raios X/métodos
13.
Br J Radiol ; 94(1127): 20201309, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34379491

RESUMO

The objective of this Pictorial Review is to describe the use of colour-coded Dual-Energy CT (DECT) to aid in the interpretation of CT Venography (CTV) of the head for emergent indications. We describe a DE CTV acquisition and post-processing technique that can be readily incorporated into clinical workflow. Colour-coded DE CTV may aid the identification and characterization of dural venous sinus abnormalities and other cerebrovascular pathologies, which can improve diagnostic confidence in emergent imaging settings.


Assuntos
Encefalopatias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Neuroimagem/métodos , Flebografia/métodos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Encéfalo/diagnóstico por imagem , Cor , Meios de Contraste , Emergências , Humanos , Iodo
14.
Am J Emerg Med ; 50: 10-13, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34271230

RESUMO

PURPOSE: To assess the association of imaging features of acute pancreatitis (AP) with the magnitude of lipase elevation in Emergency Department (ED) patients. METHODS: This Institutional Review Board-approved retrospective study included 509 consecutive patients presenting from 9/1/13-8/31/15 to a large academic ED with serum lipase levels ≥3× the upper limit of normal (ULN) (≥180 U/L). Patients were excluded if they did not have imaging (n = 131) or had a history of trauma, abdominal metastases, altered mental status, or transfer from an outside hospital (n = 190); the final study population was 188 patients. Imaging exams were retrospectively evaluated, and a consensus opinion of two subspecialty-trained abdominal radiologists was used to diagnose AP. Primary outcome was presence of imaging features of AP stratified by lipase level (≥3×-10× ULN and > 10× ULN). Secondary outcome was rate of discordant consensus evaluation compared to original radiologist's report. RESULTS: 25.0% of patients (47/188) had imaging features of AP. When lipase was >10× ULN (n = 94), patients were more likely to have imaging features of AP (34%) vs. those with mild elevation (16%) (p = 0.0042). There was moderately strong correlation between lipase level and presence of imaging features of AP (r = 0.48, p < 0.0001). Consensus review of CT and MRI images was discordant with the original report in 14.9% (28/188) of cases. CONCLUSION: Prevalence of imaging signs of AP in an ED population with lipase ≥3× ULN undergoing imaging is low. However, the probability of imaging features of AP increases as lipase value increases.


Assuntos
Serviço Hospitalar de Emergência , Lipase/sangue , Pancreatite/diagnóstico por imagem , Pancreatite/enzimologia , Biomarcadores/sangue , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
15.
Br J Radiol ; 94(1126): 20210543, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34289325

RESUMO

Radiation risks from diagnostic imaging have captured the attention of patients and medical practitioners alike, yet it remains unclear how these considerations can best be incorporated into clinical decision-making. This manuscript presents a framework to consider these issues in a potentially at-risk population, the so called "frequent flyer" patients undergoing a large amount of recurrent imaging over time. Radiation risks from the low-dose exposures of diagnostic imaging are briefly reviewed, as applied to recurrent exposures. Some scenarios are then explored in which it may be helpful to incorporate knowledge of a patient's imaging history. There is no simple or uniformly applicable approach to these challenging and often nuanced clinical decisions. The complexity and variability of the underlying disease states and trajectories argues against alerting mechanisms based on a simple cumulative dose threshold. Awareness of imaging history may instead be beneficial in encouraging physicians and patients to take the long view, and to identify those populations of frequent flyers that might benefit from alternative imaging strategies.


Assuntos
Diagnóstico por Imagem , Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomada de Decisões , Humanos , Anamnese , Monitoramento de Radiação/métodos , Radiação Ionizante , Compostos Radiofarmacêuticos , Retratamento , Fatores de Risco
16.
Phys Med ; 82: 79-86, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33601164

RESUMO

OBJECTIVES: Quantify the expected rate of CT radiation dose alerts for three body regions using accepted radiation dose benchmarks and assess key determinants of alert frequency. METHODS: This IRB-approved retrospective cohort study evaluated consecutive CT examinations performed between July and December 2013 within an academic medical system. CTDIvol x-ray tube output metrics were compared to the body-region-specific benchmark levels, Achievable Doses (AD), Diagnostic Reference Levels (DRL), and Dose Notification Values (DNV). A logistic regression model for the simulated alerts was fit as a function of the independent predictors: scanner, body region, gender, weight, and age. RESULTS: For 17,000 exams, the proportion of events triggering alerts increased with patient weight. Significant covariates were scanner, body region, patient weight and patient age (all p < 0.0001). Odds of alert generation for the AD, DRL, and DNV benchmarks increased by 7.6%, 6.6% and 2.9% per kilogram, respectively, and by 0.8%, 1.1% and -2.7% per year of age (all p < 0.0001). Compared to the most highly optimized scanner, odds of alert generation varied by a factor of 595 for AD, 1126 for DRL, and 13 for DNV. CONCLUSION: Alert frequency was significantly correlated with weight, age, body region and scanner. Controllable factors include scanner functionality and associated protocol optimization. Patient factors driving alert frequency are predominantly weight, and to a lesser degree, age. Size-agnostic fixed dose thresholds can frequently produce false positive alerts in appropriately performed exams of large patients, while missing opportunities to identify outlier scans of higher-than-expected dose in small patients.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos
17.
Emerg Radiol ; 28(1): 103-117, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32483665

RESUMO

Dual energy computed tomography (DECT), also known as spectral CT, refers to advanced CT technology that separately acquires high and low energy X-ray data to enable material characterization applications for substances that exhibit different energy-dependent x-ray absorption behavior. DECT supports a variety of post-processing applications that add value in routine clinical CT imaging, including material selective and virtual non-contrast images using two- and three-material decomposition algorithms, virtual monoenergetic imaging, and other material characterization techniques. Following a review of acquisition and post-processing techniques, we present a case-based approach to highlight the added value of DECT in common clinical scenarios. These scenarios include improved lesion detection, improved lesion characterization, improved ease of interpretation, improved prognostication, inherently more robust imaging protocols to account for unexpected pathology or suboptimal contrast opacification, length of stay reduction, reduced utilization by avoiding unnecessary follow-up examinations, and radiation dose reduction. A brief discussion of post-processing workflow approaches, challenges, and solutions is also included.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Meios de Contraste , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
18.
J Am Coll Radiol ; 17(8): 1056-1060, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32590015

RESUMO

PURPOSE: The aim of this study was to evaluate the adoption and outcomes of locally designed reporting guidelines for patients with possible coronavirus disease 2019 (COVID-19). METHODS: A departmental guideline was developed for radiologists that specified reporting terminology and required communication for patients with imaging findings suggestive of COVID-19, on the basis of patient test status and imaging indication. In this retrospective study, radiology reports completed from March 1, 2020, to May 3, 2020, that mentioned COVID-19 were reviewed. Reports were divided into patients with known COVID-19, patients with "suspected" COVID-19 (having an order indication of respiratory or infectious signs or symptoms), and "unsuspected patients" (other order indications, eg, trauma or non-chest pain). The primary outcome was the percentage of COVID-19 reports using recommended terminology; the secondary outcome was percentages of suspected and unsuspected patients diagnosed with COVID-19. Relationships between categorical variables were assessed using the Fisher exact test. RESULTS: Among 77,400 total reports, 1,083 suggested COVID-19 on the basis of imaging findings; 774 of COVID-19 reports (71%) used recommended terminology. Of 574 patients without known COVID-19 at the time of interpretation, 345 (60%) were eventually diagnosed with COVID-19, including 61% (315 of 516) of suspected and 52% (30 of 58) of unsuspected patients. Nearly all unsuspected patients (46 of 58) were identified on CT. CONCLUSIONS: Radiologists rapidly adopted recommended reporting terminology for patients with suspected COVID-19. The majority of patients for whom radiologists raised concern for COVID-19 were subsequently diagnosed with the disease, including the majority of clinically unsuspected patients. Using unambiguous terminology and timely notification about previously unsuspected patients will become increasingly critical to facilitate COVID-19 testing and contact tracing as states begin to lift restrictions.


Assuntos
Infecções por Coronavirus/diagnóstico por imagem , Fidelidade a Diretrizes/estatística & dados numéricos , Pneumonia Viral/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Radiologistas/normas , Serviço Hospitalar de Radiologia/normas , Projetos de Pesquisa/normas , COVID-19 , Estudos de Coortes , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Pandemias , Pneumonia Viral/epidemiologia , Valor Preditivo dos Testes , Radiografia Torácica/métodos , Radiografia Torácica/estatística & dados numéricos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Estados Unidos
19.
Radiographics ; 40(3): 859-874, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32364883

RESUMO

Dual-energy CT is increasingly being used in the emergency department to help diagnose acute conditions. Its applications include demonstrating bone marrow edema (BME) seen in the setting of occult fractures and other acute conditions. Dual-energy CT acquires data with two different x-ray energy spectra and is able to help differentiate materials on the basis of their differential energy-dependent x-ray absorption behaviors. Virtual noncalcium (VNCa) techniques can be used to suppress the high attenuation of trabecular bone, thus enabling visualization of subtle changes in the underlying attenuation of the bone marrow. Visualization of BME can be used to identify occult or mildly displaced fractures, pathologic fractures, metastases, and some less commonly visualized conditions such as ligamentous injuries or inflammatory arthritis. The authors' major focus is use of dual-energy CT as a diagnostic modality in the setting of trauma and to depict subtle or occult fractures. The authors also provide some scenarios in which dual-energy CT is used to help diagnose other acute conditions. The causes and pathophysiology of BME are reviewed. Dual-energy CT image acquisition and VNCa postprocessing techniques are also discussed, along with their applications in emergency settings. The authors present potential pitfalls and limitations of these techniques and their possible solutions.©RSNA, 2020.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Serviço Hospitalar de Emergência , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Doenças da Medula Óssea/fisiopatologia , Edema/fisiopatologia , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador
20.
Emerg Radiol ; 27(1): 45-50, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31673838

RESUMO

PURPOSE: To assess the radiation dose and image quality of routine dual energy CT (DECT) of the abdomen and pelvis performed in the emergency department setting, compared with single energy CT (SECT). MATERIALS AND METHODS: Seventy-five consecutive routine contrast-enhanced SECT scans of the abdomen and pelvis meeting inclusion criteria were compared with 75 routine contrast-enhanced DECT scans matched by size and patient weight (within 10 lbs), performed on the same dual-source DECT scanner. Cohorts were compared in terms of radiation dose metrics of CT dose index (CTDIvol) and dose length product (DLP), objective measurements of image quality (signal, noise, and signal-to-noise ratio of a variety of anatomical landmarks), and subjective measurements of image quality scored by two emergency radiologists. RESULTS: Demographics and patient size were not statistically different between DECT and SECT cohorts. Both average scans CTDIvol and DLP were significantly lower with DECT than with SECT. Average scan CTDIvol for SECT was 14.7 mGy (± 6.6) and for DECT was 10.9 mGy (± 3.8) (p < 0.0001). Average scan DLP for SECT was 681.5 mGy cm (± 339.3) and for DECT was 534.8 mGy cm (± 201.9) (p < 0.0001). For objective image quality metrics, for all structures measured, noise was significantly lower and SNR was significantly higher with DECT compared with SECT. For subjective image quality, for both readers, there was no significant difference between SECT and DECT in subjective image quality for soft tissues and vascular structures, or for subjective image noise. CONCLUSIONS: DECT was performed with decreased radiation dose when compared with SECT, demonstrated improved objective measurements of image quality, and equivalent subjective image quality.


Assuntos
Radiografia Abdominal/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Pontos de Referência Anatômicos , Meios de Contraste , Serviço Hospitalar de Emergência , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...